Welcome to MEIKO.
Please select a country and click "confirm".
The clean solution

KA Series Rack Conveyor Dishwashers

Discover the Clean Solution

Advanced technology. Smart design. Superior performance. You get it all with the KA Series rack conveyor system from MEIKO. The KA Series is available in standard sizes to fit any space — and with an innovative glass touchscreen panel that features both graphics and text, it’s never been easier for people and technology to work together.
Wave water

Sometimes it's fine to start off small – and even with its compact, the single-tank KA Series rack converyor still packs plenty of power to get the job done!

208V/60Hz/3Ph
230V/60Hz/3Ph
460V/60Hz/3Ph
Performance
Maximum rack capacity per hour243 / 202 / 162243 / 202 / 162243 / 202 / 162
Final rinse water volume71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.
Water consumption (per rack)0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack
Dimensions
Machine length excluding drying zone67-5/8" / 1,718 mm44” / 1118 mm44” / 1118 mm
Machine length including drying zone67-5/8" / 1,718 mm67-5/8" / 1,718 mm67-5/8" / 1,718 mm
Height76-1/8” / 1,934 mm76-1/8” / 1,934 mm76-1/8” / 1,934 mm
Depth31-1/4” / 795 mm31-1/4” / 795 mm31-1/4” / 795 mm
Passing height20” / 508 mm20” / 508 mm20” / 508 mm
Fresh water feed
Water hardness1-3 grains per gallon1-3 grains per gallon1-3 grains per gallon
Water connection
Temperature, common water connection (standard)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, fill connection (with optional WAHRS)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, rinse connection (with optional WAHRS)Cold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommended
Performance
Tank capacity21.1 gallons / 80 liters21.1 gallons / 80 liters21.1 gallons / 80 liters
Technical data
Pump motor3.0 hp / 2.2 kW3.0 hp / 2.2 kW3.0 hp / 2.2 kW
Tank heating17.2 kW18.2 kW18.2 kW
Booster heat (max.)25.2 kW25.2 kW25.2 kW
Blower dryer heat3.6 kW4.5 kW3.9 kW
Electrical connection
TB1 / TB2 / TB3 / TB 457.3 A / -- / 70.0 A / 4.0 A55.1 A / -- / 63.3 A / 4.0A29.9 A / 31.6 A / -- / --
Blower dryerTB4: +12.3 ATB4: +13.4 ATB1: +9.8 A
WAHRSTB4: +1.3 ATB4: +1.3 ATB1: +1.3 A

With 54" (1372mm) of table-to-table length, the KA-54 stands 76 1/8" (1934mm) high with a depth of 31 1/4" (795mm). The optional blower dryer adds 23 5/8" (600mm) in length.

208V/60Hz/3Ph
230V/60Hz/3Ph
460V/60Hz/3Ph
Performance
Maximum rack capacity per hour243 / 202 / 162243 / 202 / 162243 / 202 / 162
Final rinse water volume71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.
Water consumption (per rack)0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack
Dimensions
Machine length excluding drying zone54” / 1,372 mm54” / 1372mm54” / 1372mm
Machine length including drying zone77-5/8" / 1,972 mm77-5/8" / 1,972 mm77-5/8" / 1,972 mm
Height76-1/8” / 1,934 mm76-1/8” / 1,934 mm76-1/8” / 1,934 mm
Depth31-1/4” / 795 mm31-1/4” / 795 mm31-1/4” / 795 mm
Passing height20” / 508 mm20” / 508 mm20” / 508 mm
Fresh water feed
Water hardness1-3 grains per gallon1-3 grains per gallon1-3 grains per gallon
Water connection
Temperature, common water connection (standard)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, fill connection (with optional WAHRS)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, rinse connection (with optional WAHRS)Cold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommended
Performance
Tank capacity21.1 gallons / 80 liters21.1 gallons / 80 liters21.1 gallons / 80 liters
Technical data
Pump motor3.0 hp / 2.2 kW3.0 hp / 2.2 kW3.0 hp / 2.2 kW
Tank heating17.2 kW18.2 kW18.2 kW
Booster heat (max.)25.2 kW25.2 kW25.2 kW
Blower dryer heat3.6 kW4.5 kW3.9 kW
Electrical connection
TB1 / TB2 / TB3 / TB 457.3 A / -- / 70.0 A / 4.0 A55.1 A / -- / 63.3 A / 4.0A29.9 A / 31.6 A / -- / --
Blower dryerTB4: +12.3 ATB4: +13.4 ATB1: +9.8 A
WAHRSTB4: +1.3 ATB4: +1.3 ATB1: +1.3 A

With its additional wash tank, the multi-tank KA Series rack conveyor boosts your capacity even more, allowing you to handle up to
355 racks an hour. Makes the best use of space to offer outstanding performance.

208V/60Hz/3Ph
230V/60Hz/3Ph
460V/60Hz/3Ph
Performance
Maximum rack capacity per hour355 / 295 / 236355 / 295 / 236355 / 295 / 236
Final rinse water volume86 gallons (325.5 liters)/hr.86 gallons (325.5 liters)/hr.86 gallons (325.5 liters)/hr.
Water consumption (per rack)0.24 gallons (0.92 liters)/rack0.24 gallons (0.92 liters)/rack0.24 gallons (0.92 liters)/rack
Dimensions
Machine length excluding drying zone64” / 1626mm64” / 1626mm64” / 1626 mm
Machine length including drying zone87-5/8" / 2226 mm87-5/8" / 2226 mm87-5/8" / 2226 mm
Height76-1/8” / 1,934 mm76-1/8” / 1,934 mm76-1/8” / 1,934 mm
Depth31-1/4” / 795 mm31-1/4” / 795 mm31-1/4” / 795 mm
Passing height20” / 508 mm20” / 508 mm20” / 508 mm
Fresh water feed
Water hardness1-3 grains per gallon1-3 grains per gallon1-3 grains per gallon
Water connection
Temperature, common water connection (standard)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, fill connection (with optional WAHRS)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, rinse connection (with optional WAHRS)Cold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommended
Performance
Tank capacity42.2 gallons / 160 liters42.2 gallons / 160 liters42.2 gallons / 160 liters
Technical data
Pump motor3.0 hp / 2.2 kW3.0 hp / 2.2 kW3.0 hp / 2.2 kW
Tank heating17.2 kW18.2 kW18.2 kW
Power rinse tank heat18.2 kW18.2 kW
Dimensions
Width17.2 kW
Technical data
Booster heat (max.)25.2 kW25.2 kW25.2 kW
Blower dryer heat3.6 kW4.5 kW3.9 kW
Electrical connection
TB1 / TB2 / TB3 / TB 457.3 A / 57.3 A / 70.0 A / 4.0 A55.1 A / 55.1 A / 63.3 A / 4.0A57.1 A / 31.6 A / -- / --
Blower dryerTB4: +12.3 ATB4: +13.4 ATB1: +9.8 A
WAHRSTB4: +1.3 ATB4: +1.3 ATB1: +1.3 A

With 66" (1676mm) of table-to-table length, the KA-66 stands 76 1/8" (1934mm) high with a depth of 31 1/4" (795mm). The optional blower dryer adds 23 5/8" (600mm) in length.

208V/60Hz/3Ph
230V/60Hz/3Ph
460V/60Hz/3Ph
Performance
Maximum rack capacity per hour243 / 202 / 162243 / 202 / 162243 / 202 / 162
Final rinse water volume71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.
Water consumption (per rack)0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack
Dimensions
Machine length excluding drying zone66” / 1,676 mm66” / 1,676 mm66” / 1,676 mm
Machine length including drying zone89-5/8" / 2,276 mm89-5/8" / 2,276 mm89-5/8" / 2,276 mm
Height76-1/8” / 1,934 mm76-1/8” / 1,934 mm76-1/8” / 1,934 mm
Depth31-1/4” / 795 mm31-1/4” / 795 mm31-1/4” / 795 mm
Passing height20” / 508 mm20” / 508 mm20” / 508 mm
Fresh water feed
Water hardness1-3 grains per gallon1-3 grains per gallon1-3 grains per gallon
Water connection
Temperature, common water connection (standard)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, fill connection (with optional WAHRS)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, rinse connection (with optional WAHRS)Cold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommended
Performance
Tank capacity21.1 gallons / 80 liters21.1 gallons / 80 liters21.1 gallons / 80 liters
Technical data
Pump motor3.0 hp / 2.2 kW3.0 hp / 2.2 kW3.0 hp / 2.2 kW
Tank heating17.2 kW18.2 kW18.2 kW
Booster heat (max.)25.2 kW25.2 kW25.2 kW
Blower dryer heat3.6 kW4.5 kW3.9 kW
Electrical connection
TB1 / TB2 / TB3 / TB 457.3 A / -- / 70.0 A / 4.0 A55.1 A / -- / 63.3 A / 4.0A29.9 A / 31.6 A / -- / --
Blower dryerTB4: +12.3 ATB4: +13.4 ATB1: +9.8 A
WAHRSTB4: +1.3 ATB4: +1.3 ATB1: +1.3 A

With 76" (1930mm) of table-to-table length, the KA-76 stands 76 1/8" (1934mm) high with a depth of 31 1/4" (795mm). The optional blower dryer adds 23 5/8" (600mm) in length.

208V/60Hz/3Ph
230V/60Hz/3Ph
460V/60Hz/3Ph
Performance
Maximum rack capacity per hour243 / 202 / 162243 / 202 / 162243 / 202 / 162
Final rinse water volume71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.
Water consumption (per rack)0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack
Dimensions
Machine length excluding drying zone76” / 1,930 mm76” / 1,930 mm76” / 1,930 mm
Machine length including drying zone99-5/8" / 2,530 mm99-5/8" / 2,530 mm99-5/8" / 2,530 mm
Height76-1/8” / 1,934 mm76-1/8” / 1,934 mm76-1/8” / 1,934 mm
Depth31-1/4” / 795 mm31-1/4” / 795 mm31-1/4” / 795 mm
Passing height20” / 508 mm20” / 508 mm20” / 508 mm
Fresh water feed
Water hardness1-3 grains per gallon1-3 grains per gallon1-3 grains per gallon
Water connection
Temperature, common water connection (standard)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, fill connection (with optional WAHRS)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, rinse connection (with optional WAHRS)Cold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommended
Performance
Tank capacity21.1 gallons / 80 liters21.1 gallons / 80 liters21.1 gallons / 80 liters
Technical data
Pump motor3.0 hp / 2.2 kW3.0 hp / 2.2 kW3.0 hp / 2.2 kW
Tank heating17.2 kW18.2 kW18.2 kW
Booster heat (max.)25.2 kW25.2 kW25.2 kW
Blower dryer heat3.6 kW4.5 kW3.9 kW
Electrical connection
TB1 / TB2 / TB3 / TB 457.3 A / -- / 70.0 A / 4.0 A55.1 A / -- / 63.3 A / 4.0A29.9 A / 31.6 A / -- / --
Blower dryerTB4: +12.3 ATB4: +13.4 ATB1: +9.8 A
WAHRSTB4: +1.3 ATB4: +1.3 ATB1: +1.3 A

With 80" (2032mm) of table-to-table length, the KA-80 stands 76 1/8" (1934mm) high with a depth of 31 1/4" (795mm). The optional blower dryer adds 23 5/8" (600mm) in length.

208V/60Hz/3Ph
230V/60Hz/3Ph
460V/60Hz/3Ph
Performance
Maximum rack capacity per hour243 / 202 / 162243 / 202 / 162243 / 202 / 162
Final rinse water volume71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.
Water consumption (per rack)0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack
Dimensions
Machine length excluding drying zone80” / 2,032 mm80” / 2,032 mm80” / 2,032 mm
Machine length including drying zone103-5/8" / 2,632 mm103-5/8" / 2,632 mm103-5/8" / 2,632 mm
Height76-1/8” / 1,934 mm76-1/8” / 1,934 mm76-1/8” / 1,934 mm
Depth31-1/4” / 795 mm31-1/4” / 795 mm31-1/4” / 795 mm
Passing height20” / 508 mm20” / 508 mm20” / 508 mm
Fresh water feed
Water hardness1-3 grains per gallon1-3 grains per gallon1-3 grains per gallon
Water connection
Temperature, common water connection (standard)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, fill connection (with optional WAHRS)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, rinse connection (with optional WAHRS)Cold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommended
Performance
Tank capacity42.2 gallons / 160 liters42.2 gallons / 160 liters42.2 gallons / 160 liters
Technical data
Pump motor3.0 hp / 2.2 kW3.0 hp / 2.2 kW3.0 hp / 2.2 kW
Tank heating17.2 kW18.2 kW18.2 kW
Booster heat (max.)25.2 kW25.2 kW25.2 kW
Blower dryer heat3.6 kW4.5 kW3.9 kW
Electrical connection
TB1 / TB2 / TB3 / TB 457.3 A / -- / 70.0 A / 13.5 A55.1 A / -- / 63.3 A / 13.5 A34.3 A / 31.6 A / -- / --
Blower dryerTB4: +12.3 ATB4: +13.4 ATB1: +9.8 A
WAHRSTB4: +1.3 ATB4: +1.3 ATB1: +1.3 A

With 86" (2184mm) of table-to-table length, the KA-86 stands 76 1/8" (1934mm) high with a depth of 31 1/4" (795mm). The optional blower dryer adds 23 5/8" (600mm) in length.

208V/60Hz/3Ph
230V/60Hz/3Ph
460V/60Hz/3Ph
Performance
Maximum rack capacity per hour355 / 295 / 236355 / 295 / 236355 / 295 / 236
Final rinse water volume71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.
Water consumption (per rack)0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack
Dimensions
Machine length excluding drying zone86” / 2184mm86” / 2184mm86” / 2184mm
Machine length including drying zone99-5/8" / 2,784 mm99-5/8" / 2,784 mm99-5/8" / 2,784 mm
Height76-1/8” / 1,934 mm76-1/8” / 1,934 mm76-1/8” / 1,934 mm
Depth31-1/4” / 795 mm31-1/4” / 795 mm31-1/4” / 795 mm
Passing height20” / 508 mm20” / 508 mm20” / 508 mm
Fresh water feed
Water hardness1-3 grains per gallon1-3 grains per gallon1-3 grains per gallon
Water connection
Temperature, common water connection (standard)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, fill connection (with optional WAHRS)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, rinse connection (with optional WAHRS)Cold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommended
Performance
Tank capacity42.2 gallons / 160 liters42.2 gallons / 160 liters42.2 gallons / 160 liters
Technical data
Pump motor3.0 hp / 2.2 kW3.0 hp / 2.2 kW3.0 hp / 2.2 kW
Tank heating17.2 kW18.2 kW18.2 kW
Power rinse tank heat17.2 kW18.2 kW18.2 kW
Booster heat (max.)25.2 kW25.2 kW25.2 kW
Blower dryer heat3.6 kW4.5 kW3.9 kW
Electrical connection
TB1 / TB2 / TB3 / TB 457.3 A / 57.3 A / 70.0 A / 4.0 A55.1 A / 55.1 A / 63.3 A / 4.0A57.1 A / 31.6 A / -- / --
Blower dryerTB4: +12.3 ATB4: +13.4 ATB1: +9.8 A
WAHRSTB4: +1.3 ATB4: +1.3 ATB1: +1.3 A

With 90" (2286mm) of table-to-table length, the KA-90 stands 76 1/8" (1934mm) high with a depth of 31 1/4" (795mm). The optional blower dryer adds 23 5/8" (600mm) in length.

208V/60Hz/3Ph
230V/60Hz/3Ph
460V/60Hz/3Ph
Performance
Maximum rack capacity per hour243 / 202 / 162243 / 202 / 162243 / 202 / 162
Final rinse water volume71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.71 gallons (268.8 liters)/hr.
Water consumption (per rack)0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack0.29 gallons (1.11 liters)/rack
Dimensions
Machine length excluding drying zone90” / 2,286mm90” / 2,286mm90” / 2,286mm
Machine length including drying zone113-5/8” / 2886mm113-5/8” / 2886mm113-5/8” / 2886mm
Height76-1/8” / 1,934 mm76-1/8” / 1,934 mm76-1/8” / 1,934 mm
Depth31-1/4” / 795 mm31-1/4” / 795 mm31-1/4” / 795 mm
Passing height20” / 508 mm20” / 508 mm20” / 508 mm
Fresh water feed
Water hardness1-3 grains per gallon1-3 grains per gallon1-3 grains per gallon
Water connection
Temperature, common water connection (standard)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, fill connection (with optional WAHRS)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, rinse connection (with optional WAHRS)Cold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommended
Performance
Tank capacity42.2 gallons / 160 liters42.2 gallons / 160 liters42.2 gallons / 160 liters
Technical data
Pump motor3.0 hp / 2.2 kW3.0 hp / 2.2 kW3.0 hp / 2.2 kW
Tank heating17.2 kW18.2 kW18.2 kW
Booster heat (max.)25.2 kW25.2 kW25.2 kW
Blower dryer heat3.6 kW4.5 kW3.9 kW
Electrical connection
TB1 / TB2 / TB3 / TB 457.3 A / -- / 70.0 A / 13.5 A55.1 A / -- / 63.3 A / 13.5 A34.3 A / 31.6 A / -- / --
Blower dryerTB4: +12.3 ATB4: +13.4 ATB1: +9.8 A
WAHRSTB4: +1.3 ATB4: +1.3 ATB1: +1.3 A

With 100" (2540mm) of table-to-table length, the KA-100 stands 76 1/8" (1934mm) high with a depth of 31 1/4" (795mm). The optional blower dryer adds 23 5/8" (600mm) in length.

208V/60Hz/3Ph
230V/60Hz/3Ph
460V/60Hz/3Ph
Performance
Maximum rack capacity per hour355 / 295 / 236355 / 295 / 236355 / 295 / 236
Final rinse water volume86 gallons (325.5 liters)/hr.86 gallons (325.5 liters)/hr.86 gallons (325.5 liters)/hr.
Water consumption (per rack)0.24 gallons (0.92 liters)/rack0.24 gallons (0.92 liters)/rack0.24 gallons (0.92 liters)/rack
Dimensions
Machine length excluding drying zone100” / 2,540 mm100” / 2,540 mm100” / 2,540 mm
Machine length including drying zone123-5/8” / 2,540 mm123-5/8” / 2,540 mm123-5/8” / 2,540 mm
Height76-1/8” / 1,934 mm76-1/8” / 1,934 mm76-1/8” / 1,934 mm
Depth31-1/4” / 795 mm31-1/4” / 795 mm31-1/4” / 795 mm
Passing height20” / 508 mm20” / 508 mm20” / 508 mm
Fresh water feed
Water hardness1-3 grains per gallon1-3 grains per gallon1-3 grains per gallon
Water connection
Temperature, common water connection (standard)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, fill connection (with optional WAHRS)110-140°F / 43-60°C110-140°F / 43-60°C110-140°F / 43-60°C
Temperature, rinse connection (with optional WAHRS)Cold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommendedCold as available, 53-68°F / 12-20° C recommended
Performance
Tank capacity63.3 gallons / 240 liters63.3 gallons / 240 liters63.3 gallons / 240 liters
Technical data
Pump motor3.0 hp / 2.2 kW3.0 hp / 2.2 kW3.0 hp / 2.2 kW
Tank heating17.2 kW18.2 kW18.2 kW
Power rinse tank heat17.2 kW18.2 kW18.2 kW
Booster heat (max.)25.2 kW25.2 kW25.2 kW
Blower dryer heat3.6 kW4.5 kW3.9 kW
Electrical connection
TB1 / TB2 / TB3 / TB 457.3 A / 57.3 A / 70.0 A / 13.5 A55.1 A / 55.1 A / 63.3 A / 13.5 A61.5 A / 31.6 A / -- / --
Blower dryerTB4: +12.3 ATB4: +13.4 ATB1: +9.8 A
WAHRSTB4: +1.3 ATB4: +1.3 ATB1: +1.3 A